Looking ahead, InfiniBand will be moving to 64/66 encoding, which the InfiniBand Trade Association says is a lot more efficient than the 8b/10b encoding. In the new method, you send 66 bits for every 64 bits of data, yielding only slightly more than a three per cent overhead for the protocol, compared to a 25 per cent overhead with the prior encoding. (The lane speeds above include the encoding overhead.) The upshot is that a much larger portion of the bandwidth in an InfiniBand device using the 64/66 encoding will be available for sending data.

Starting in 2011, there will be two new lane speeds for InfiniBand. The first is FDR — which is not short for the 32nd president of the United States, but for Fourteen Data Rate, referring to its 14Gb/sec speed. The second is called EDR, short for Eight Data Rate, which actually runs the InfiniBand lanes at 25Gb/sec.

The FDR line speed was added to allow for the creation of lower-power and less-expensive InfiniBand gear that nonetheless has more oomph than the current QDR products. EDR obviously targets the high end of the bandwidth range, with switch-to-switch 12x products being able to hit 312Gb/sec bandwidth compared to 168Gb/sec for FDR products.

At the server switch level, the 4x ports will deliver 104Gb/sec using the EDR lanes, significantly faster than the 80Gb/sec that was projected a few years back for 2011 on the InfiniBand roadmap for EDR. Sparks says that FDR is aimed mostly at blade servers, where compact packaging and low heat are priorities.

No matter what speed InfiniBand hits, the PCI Express 3.0 bus is going to be the bottleneck. That spec was originally due in late 2009, but has run into delays. The multi-lane PCI Express I/O architecture will support 8GT/sec of bandwidth, up from 5GT/sec with PCI Express 2.0 slots. While PCI Express 3.0 will ditch the 8b/10b encoding, it is not clear if the peripheral standard will use the same 64/66 encoding used by the future InfiniBand protocol, a 128b/130b encoding scheme, or something else.

The InfiniBand roadmap already had a Hexidecimal Data Rate (HDR) plotted out on the roadmap. The InfiniBand cheerleaders did not offer the feeds and speeds for HDR two years ago, as they have not here in 2010, but now they are putting a stake in the ground and saying that HDR, whatever it is, will come out in 2014.

The updated InfiniBand roadmap also includes a pointer to something called NDR, short for Next Data Rate, which comes after that. No word on what NDR speeds might be or when they are expected to be available. The basic curve is to double bandwidth every three years, so that would put HDR at around 50Gb/sec per lane in 2014 and NDR at 100Gb/sec per lane in 2017, with possible slower offshoots, like the geared-down FDR relative to the EDR, in the next generation of HDR and NDR products.

The good folks at the PCI-SIG better get in gear and start getting PCI Express 4.0 and 5.0 on the boards. There's no point in worrying about InfiniBand bandwidth of it will simply choke the PCI bus. Then again, system makers could just do something interesting and go back to the original InfiniBand plan, which was to use InfiniBand for peripherals as well as for switched fabrics.

Wouldn't that just make Cisco CEO John Chambers' day? ®

Internet Security Threat Report 2014

More from The Register

next story
Azure TITSUP caused by INFINITE LOOP
Fat fingered geo-block kept Aussies in the dark
NASA launches new climate model at SC14
75 days of supercomputing later ...
Yahoo! blames! MONSTER! email! OUTAGE! on! CUT! CABLE! bungle!
Weekend woe for BT as telco struggles to restore service
You think the CLOUD's insecure? It's BETTER than UK.GOV's DATA CENTRES
We don't even know where some of them ARE – Maude
Cloud unicorns are extinct so DiData cloud mess was YOUR fault
Applications need to be built to handle TITSUP incidents
BOFH: WHERE did this 'fax-enabled' printer UPGRADE come from?
Don't worry about that cable, it's part of the config
Stop the IoT revolution! We need to figure out packet sizes first
Researchers test 802.15.4 and find we know nuh-think! about large scale sensor network ops
DEATH by COMMENTS: WordPress XSS vuln is BIGGEST for YEARS
Trio of XSS turns attackers into admins
prev story

Whitepapers

Why and how to choose the right cloud vendor
The benefits of cloud-based storage in your processes. Eliminate onsite, disk-based backup and archiving in favor of cloud-based data protection.
Forging a new future with identity relationship management
Learn about ForgeRock's next generation IRM platform and how it is designed to empower CEOS's and enterprises to engage with consumers.
10 ways wire data helps conquer IT complexity
IT teams can automatically detect problems across the IT environment, spot data theft, select unique pieces of transaction payloads to send to a data source, and more.
5 critical considerations for enterprise cloud backup
Key considerations when evaluating cloud backup solutions to ensure adequate protection security and availability of enterprise data.
High Performance for All
While HPC is not new, it has traditionally been seen as a specialist area – is it now geared up to meet more mainstream requirements?