The number of panels wetted determines the amount of cooling provided; the hotter the incoming air, the more panels the system will automatically activate. In normal operation, the system's main energy usage consists of the 200w water pump that keeps the cooler wet.

In the event of over-cooling, a bypass damper allows some or all the air to enter at ambient temperature. According to Vaney, under-cooling has not been an issue, apart from in rare climates such as Singapore, with both very high temperatures and very high humidities.

But does it trap cooking odours

If that becomes an issue, traditional chilling coils are in the air's path and can be activated if necessary. But according to Vaney, "we get 99.74 percent free cooling in the UK, or if humidity reaches 80 percent, all cooling is free".

After that, the air is pulled through further silencing material, making it one of the few such facilities in which you can hold a conversation without shouting. And because they're warmer than most, you don't freeze either.

Once in the data centre, the air passes along cold corridors and through louvred doors. These louvres are designed to open and close to keep incoming air at the right temperature. The cold aisle is completely enclosed - there's no raised floor - so that all the cooled air passes through the rack, impelled by the servers' fans into the hot aisle, from where it is exhausted into the environment.

The system has been independently tested using ambient air temperatures of up to 35 degrees c, reckons Vaney, and the system works in freezing ambient temperatures by mixing warm exhaust air with incoming air.

The facility is littered with sensors and feedback air passages to allow the control system to understand exactly what's happening to the air at all stages of the process, as a result of which it needs little human intervention. Rogers reckons that the company is claiming patents on several of the techniques used, and so was loath to tell me exactly how it works. Among the benefits of this tight control is that the system only delivers the volume of air demanded by the servers, so saving more energy.

Bladeroom makes its data centre available as modules weighing up to 20 tonnes, with everything all wired up and ready to go, including servers. If you want one, you buy the number of modules you need, and they arrive on the back of a series of lorries, shipped from the company's HQ on the outskirts of a Gloucestershire village. And if you want to make it bigger, you just buy more modules.

Is this the future of datacentre design? ®

Choosing a cloud hosting partner with confidence

Whitepapers

Providing a secure and efficient Helpdesk
A single remote control platform for user support is be key to providing an efficient helpdesk. Retain full control over the way in which screen and keystroke data is transmitted.
Saudi Petroleum chooses Tegile storage solution
A storage solution that addresses company growth and performance for business-critical applications of caseware archive and search along with other key operational systems.
Security and trust: The backbone of doing business over the internet
Explores the current state of website security and the contributions Symantec is making to help organizations protect critical data and build trust with customers.
Reg Reader Research: SaaS based Email and Office Productivity Tools
Read this Reg reader report which provides advice and guidance for SMBs towards the use of SaaS based email and Office productivity tools.
Security for virtualized datacentres
Legacy security solutions are inefficient due to the architectural differences between physical and virtual environments.